Anesthesia
- Intensive care |
|
| |
Vascular
surgery |
|
| |
Gynecology |
|
| |
Gastro-enterology |
|
| |
Subcontracting |
|
| |
OEM
/ Distribution |
|
|
|
| BALLOON
CATHETERS FOR ARTERIAL EMBOLECTOMY |
|
CATHETER FOR EMBOLECTOMY
The soft and short tip allows an easy arterial insertion
reducing plaque dissection.
The balloon is VERY RESISTANT and cylinder shaped after
inflation.
Available sizes : 2F to 8F, usually 80, 60, or 40 cm long.
Balloon Inflation :
With a sterile chloride solution of sodium or possibly
which may contain a non particulate and diluted radio
opaque solution. These catheters should not be used in
the venous system, their tip is not designed for the venous
system.
|
|
|
|
| TECHNICAL
CHARACTERISTICS |
| Reference |
Size
in F |
Length
in cm |
color |
Balloon
volume in mL |
Balloon
diameter inflated in mm |
| 2210100 |
2 |
40 |
|
*0,10 |
4 |
| 2210300 |
2 |
60 |
|
*0,20 |
4 |
| 2210500 |
2 |
80 |
|
0,20 |
5 |
| 2210700 |
3 |
40 |
|
0,20 |
5 |
| 2211100 |
3 |
80 |
|
0,20 |
5 |
| 2211400 |
4 |
40 |
|
0,75 |
7 |
| 2211800 |
4 |
80 |
|
0,75 |
7 |
| 2212100 |
5 |
40 |
|
1,50 |
9 |
| 2212300 |
5 |
80 |
|
1,50 |
9 |
| 2212600 |
6 |
40 |
|
2,00 |
11 |
| 2212800 |
6 |
80 |
|
2,00 |
11 |
| 2213300 |
7 |
80 |
|
2,50 |
13 |
| 2213700 |
8 |
80 |
|
3,00 |
14 |
(*)with liquid or with gas
|
Double lumen catheter :
For embolectomy allowing the upstream injection of a product
(e.g. : heparin)
Double lumens are distal. Proximal upon request
|
| Two
lumens |
| Reference |
Size
in F |
Length
in cm |
color |
Balloon
volume in mL |
Balloon
diameter inflated in mm |
| 2214100 |
3 |
80 |
|
|
|
| 2214200 |
4 |
80 |
|
0,75 |
7 |
| 2214600 |
5 |
80 |
|
1,50 |
9 |
| 2214900 |
6 |
80 |
|
2,00 |
11 |
| 2215300 |
7 |
80 |
|
2,50 |
13 |
|
USE
For single use only
Sterilized with ethylene oxide gas (ETO)
INFLATING THE BALLOON
Before use, inflate then deflate the balloon.
Do not exceed the indicated maximum balloon capacity,
as this may cause a rupture of the latex balloon.
Air should not be used to inflate balloons, the balloon
rupture during use could cause an air embolus. The balloon
should be inflated with a sterile, pyrogen-free water
or saline solution.
STORAGE
They should be stored in a dry, cool place.
The packaging is designed to avoid the crushing of the
catheter.
The ageing of the balloon is accelerated when latex is
exposed to atmosphere and direct sunlight.
LAL test dosage of endotoxines.
|
For
further information :
Phone : +33 (0)3.44.26.63.46
Fax : +33 (0)3.44.26.93.37
E-mail
: contact@prodimed.com
|
Back to the top 
Copyright © 2008 PRODIMED & PRODIMED Division PLASTIMED
|
|